Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Bras Ortop (Sao Paulo) ; 57(2): 223-229, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35652014

RESUMO

Objective To define the epidemiological profile and the associated comorbidities of patients submitted to total knee arthroplasty (TKA) in two reference hospitals. Materials and Methods During the present cross-sectional observational study, 294 patients submitted to TKA were evaluated in 2 tertiary care hospitals. The diagnosis of self-reported comorbidities was collected by direct interview. The Functional Comorbidity Index (FCI) and the 5-Factor Modified Frailty Index (mFI-5) were calculated. The incidence of comorbidities and their relationship with the calculated indexes were evaluated. Results Most of the patients in the sample were women ( p = 0.000) between the seventh and eighth decades of life. Systemic arterial hypertension was the most common pathology, followed by obesity and diabetes mellitus. The FCI presented a direct relationship with females ( p = 0.038) and obesity ( p < 0.001). The mFI-5 was only associated to obesity ( p = 0.022), demonstrating a higher chance of complications in this group. Conclusion Patients undergoing TKA are essentially carriers of clinical comorbidities that can negatively influence functional results and compromise the safety of the procedure. The identification of risk factors can contribute to the safety and better selection of TKA candidates.

2.
Rev. bras. ortop ; 57(2): 223-229, Mar.-Apr. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1387999

RESUMO

Abstract Objective To define the epidemiological profile and the associated comorbidities of patients submitted to total knee arthroplasty (TKA) in two reference hospitals. Methods During the present cross-sectional observational study, 294 patients submitted to TKA were evaluated in 2 tertiary care hospitals. The diagnosis of selfreported comorbidities was collected by direct interview. The Functional Comorbidity Index (FCI) and the 5-Factor Modified Frailty Index (mFI-5) were calculated. The incidence of comorbidities and their relationship with the calculated indexes were evaluated. Results Most of the patients in the sample were women (p» 0.000) between the seventh and eighth decades of life. Systemic arterial hypertension was the most common pathology, followed by obesity and diabetes mellitus. The FCI presented a direct relationship with females (p» 0.038) and obesity (p< 0.001). The mFI-5 was only associated to obesity (p» 0.022), demonstrating a higher chance of complications in this group. Conclusion Patients undergoing TKA are essentially carriers of clinical comorbidities that can negatively influence functional results and compromise the safety of the procedure. The identification of risk factors can contribute to the safety and better selection of TKA candidates.


Resumo Objetivo Definir o perfil epidemiológico e as comorbidades associadas dos pacientes submetidos à artroplastia total do joelho (ATJ) em dois hospitais de referência. Métodos Durante o estudo observacional transversal, foram avaliados 294 pacientes submetidos à ATJ em 2 hospitais de atenção terciária. Coletou-se, por entrevista direta, o diagnóstico das comorbidades auto-relatadas. Foram calculados o índice de comorbidades funcionais (do inglês Functional Comorbidity Index, FCI) e o índice modificado de cinco fatores de fragilidade (do inglês 5-Factor Modified Frailty Index, mFI-5). Avaliou-se a incidência das comorbidades e a relação destas com os índices calculados. Resultados A maioria dos pacientes da amostra foram mulheres (p» 0,000) entre a sétima e oitava décadas de vida. A hipertensão arterial sistêmica foi a patologia mais comum, seguida de obesidade e diabetes mellitus. O ICFapresentou uma relação direta com sexo feminino (p» 0,038) e a obesidade (p< 0,001). O mFI-5 apresentou relação somente com a obesidade (p» 0,022), e demonstrou uma chance maior de complicações nesse grupo. Conclusão Os pacientes submetidos à ATJ são essencialmente portadores de comorbidades clínicas que podem influenciar negativamente os resultados funcionais e comprometer a segurança do procedimento. A identificação dos fatores de risco pode contribuir para a segurança e melhor seleção dos candidatos a ATJ.


Assuntos
Humanos , Masculino , Feminino , Complicações Pós-Operatórias/epidemiologia , Perfil de Saúde , Comorbidade , Artroplastia do Joelho
3.
Radiol Bras ; 50(3): 170-175, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28670028

RESUMO

OBJECTIVE: To compare intraoperative measurements of the knee with those obtained by magnetic resonance imaging, in order to validate the latter method for use in anthropometric studies. MATERIALS AND METHODS: We studied 20 knees in 20 patients with osteoarthritis, all of whom underwent total arthroplasty between August and December of 2013. We took six measurements in the distal femur and two in the proximal tibia. Using the information system of the institution, we made the measurements on magnetic resonance imaging scans that had been obtained in the axial plane. Intraoperative measurements were obtained using a caliper, after the initial cuts made during the arthroplasty. The anatomical parameters determined by magnetic resonance imaging were the same as those determined by intraoperative measurement. The intraclass correlation coefficient was used in order to assess the level of agreement in anthropometric measurements of the knee performed by magnetic resonance imaging and by intraoperative measurement. RESULTS: Statistical analysis revealed a highly significant correlation between the knee anthropometric parameters of the knee determined by intraoperative measurement and those determined by magnetic resonance imaging. CONCLUSION: The dimensions of osteoarthritic knees measured by magnetic resonance imaging were similar to those measured intraoperatively. Therefore, magnetic resonance imaging can be considered a reliable method for use in large-scale anthropometric studies that will allow the available implants to be adapted and improved.


OBJETIVO: Comparar a mensuração do joelho realizada por meio de ressonância magnética com a medida obtida intraoperatoriamente, a fim de validar o método para estudos antropométricos. MATERIAIS E MÉTODOS: Foram estudados 20 joelhos em 20 pacientes portadores de osteoartrite submetidos a artroplastia total, entre agosto e dezembro de 2013. Realizaram-se seis medidas no fêmur distal e duas na tíbia proximal. As mensurações nas imagens foram feitas no plano axial, por meio do sistema informatizado da instituição. As mensurações intraoperatórias foram obtidas utilizando-se um paquímetro, após os cortes iniciais da artroplastia. Os parâmetros anatômicos foram os mesmos. O coeficiente de correlação intraclasses foi utilizado para avaliar a concordância nas medidas antropométricas de joelho realizadas pela ressonância magnética e pelo paquímetro de forma intraoperatória. RESULTADOS: A análise estatística revelou que existe concordância altamente significativa entre as medidas antropométricas do joelho conseguidas por meio do uso do paquímetro intraoperatoriamente e pela ressonância magnética. CONCLUSÃO: A mensuração das dimensões dos joelhos osteoartríticos por meio de ressonância magnética apresentou-se como método semelhante à mensuração intraoperatória, sendo confiável para a realização de estudos antropométricos amplos que permitam a adequação e melhoria de implantes disponíveis.

4.
Radiol. bras ; 50(3): 170-175, May-June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-896081

RESUMO

Abstract Objective: To compare intraoperative measurements of the knee with those obtained by magnetic resonance imaging, in order to validate the latter method for use in anthropometric studies. Materials and Methods: We studied 20 knees in 20 patients with osteoarthritis, all of whom underwent total arthroplasty between August and December of 2013. We took six measurements in the distal femur and two in the proximal tibia. Using the information system of the institution, we made the measurements on magnetic resonance imaging scans that had been obtained in the axial plane. Intraoperative measurements were obtained using a caliper, after the initial cuts made during the arthroplasty. The anatomical parameters determined by magnetic resonance imaging were the same as those determined by intraoperative measurement. The intraclass correlation coefficient was used in order to assess the level of agreement in anthropometric measurements of the knee performed by magnetic resonance imaging and by intraoperative measurement. Results: Statistical analysis revealed a highly significant correlation between the knee anthropometric parameters of the knee determined by intraoperative measurement and those determined by magnetic resonance imaging. Conclusion: The dimensions of osteoarthritic knees measured by magnetic resonance imaging were similar to those measured intraoperatively. Therefore, magnetic resonance imaging can be considered a reliable method for use in large-scale anthropometric studies that will allow the available implants to be adapted and improved.


Resumo Objetivo: Comparar a mensuração do joelho realizada por meio de ressonância magnética com a medida obtida intraoperatoriamente, a fim de validar o método para estudos antropométricos. Materiais e Métodos: Foram estudados 20 joelhos em 20 pacientes portadores de osteoartrite submetidos a artroplastia total, entre agosto e dezembro de 2013. Realizaram-se seis medidas no fêmur distal e duas na tíbia proximal. As mensurações nas imagens foram feitas no plano axial, por meio do sistema informatizado da instituição. As mensurações intraoperatórias foram obtidas utilizando-se um paquímetro, após os cortes iniciais da artroplastia. Os parâmetros anatômicos foram os mesmos. O coeficiente de correlação intraclasses foi utilizado para avaliar a concordância nas medidas antropométricas de joelho realizadas pela ressonância magnética e pelo paquímetro de forma intraoperatória. Resultados: A análise estatística revelou que existe concordância altamente significativa entre as medidas antropométricas do joelho conseguidas por meio do uso do paquímetro intraoperatoriamente e pela ressonância magnética. Conclusão: A mensuração das dimensões dos joelhos osteoartríticos por meio de ressonância magnética apresentou-se como método semelhante à mensuração intraoperatória, sendo confiável para a realização de estudos antropométricos amplos que permitam a adequação e melhoria de implantes disponíveis.

5.
Rev. bras. ortop ; 51(4): 400-404, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-792731

RESUMO

ABSTRACT OBJECTIVE: To evaluate the relationship between patients' body mass index (BMI) and the degree of radiographic severity of knee osteoarthrosis. METHOD: 117 patients with gonarthrosis were evaluated prospectively. The patients' BMI was calculated and their knee arthrosis was classified in accordance with the modified Ahlbäck criteria. Kruskal-Wallis analysis of variance (ANOVA) was used to evaluate the relationship between these two variables. RESULTS: The group classified as Ahlbäck grade V had significantly higher BMI than the others. CONCLUSION: There is a direct relationship between BMI and the degree of radiographic severity of gonarthrosis. Obesity appears to be directly related to the progression of knee osteoarthrosis.


RESUMO OBJETIVO: Avaliar a relação do índice de massa corporal (IMC) do paciente com o grau de gravidade radiográfica da osteoartrose do joelho. MÉTODO: Foram avaliados, de forma prospectiva, 117 pacientes portadores de gonartrose. Os pacientes tiveram seus índices de massa corporal calculados e a artrose do joelho foi classificada segundo os critérios de Ahlbäck modificados. Usou-se a Anova de Kruskal-Wallis para avaliar a relação entre essas duas variáveis. RESULTADOS: O grupo classificado como grau V de Ahlbäck apresentou um IMC significativamente maior do que os demais. CONCLUSÃO: Existe relação direta entre o IMC e o grau de gravidade radiográfico da gonartrose. A obesidade parece estar diretamente relacionada à progressão da osteoartrose do joelho.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia , Joelho , Obesidade , Osteoartrite
6.
Rev. bras. ortop ; 51(3): 282-289, tab, graf
Artigo em Inglês | LILACS | ID: lil-787726

RESUMO

To define the anthropometric profile of the knee in a Brazilian population with gonarthrosis using intraoperative measurements; and to evaluate the compatibility of three implants available for total knee arthroplasty. METHODS: Morphometric data were collected prospectively from 117 subjects with gonarthrosis. Six dimensions in the distal femur and two in the proximal tibia were documented in 118 knees while performing total arthroplasty. These data were compared with the dimensions of three implants available for total knee arthroplasty. RESULTS: The statistical analysis showed that more than a quarter of the patients presented an unsatisfactory relationship between the knee and prosthesis. CONCLUSION: The implants evaluated need to be adjusted to better fit Brazilian patients.


Definir o perfil antropométrico do joelho em população brasileira portadora de gonartrose, com o uso da mensuração intraoperatória, e avaliar a compatibilidade de três implantes disponíveis para artroplastia total do joelho. MÉTODOS: Foram coletados, de forma prospectiva, os dados morfométricos de 117 pacientes portadores de gonartrose. Documentaram-se seis dimensões no fêmur distal e duas na tíbia proximal em 118 joelhos, durante a artroplastia total. Esses dados foram comparados com as dimensões dos três implantes disponíveis para artroplastia total do joelho. RESULTADOS: A análise estatística revelou que mais de um quarto dos pacientes apresentou relação inadequada entre os joelhos e as próteses. CONCLUSÃO: Os implantes avaliados necessitam de ajustes para melhor atender aos pacientes brasileiros.


Assuntos
Humanos , Masculino , Feminino , Antropometria , Artroplastia do Joelho , Fêmur
7.
Radiol Bras ; 48(5): 282-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26543278

RESUMO

OBJECTIVE: To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter. MATERIALS AND METHODS: A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software. RESULTS: The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from -2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from -2.09° to 12.2°. CONCLUSION: The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.


OBJETIVO: Definir o padrão de rotação do fêmur distal em população brasileira, correlacionar esse padrão com o sugerido pelos instrumentais de artroplastia e analisar a variabilidade de cada parâmetro anatômico. MATERIAIS E MÉTODOS: Foram avaliados 101 exames de ressonância magnética no período compreendido entre abril e junho de 2012. A coleta dos dados epidemiológicos foi feita pelo sistema informatizado da instituição de imagem, sendo 52 pacientes masculinos e 49 femininos. As mensurações foram feitas no plano axial, correlacionando e triangulando com os outros planos. Utilizamos como referência para as medidas angulares a linha condilar posterior. Na sequência, especificamos o eixo transepicondilar anatômico, cirúrgico e a linha troclear anteroposterior. As angulações entre a linha de referência e as linhas estudadas foram calculadas pelo software da instituição. RESULTADOS: Foi encontrada uma média de 6,89° na aferição do eixo transepicondilar anatômico em relação à linha condilar posterior, variando de 0,25° a 12°. O eixo transepicondilar cirúrgico apresentou média de 2,89°, variando de ­2,23° (rotação interna) a 7,86°. O eixo perpendicular à linha troclear anteroposterior apresentou média de 4,77°, variando de ­2,09° a 12,2°. CONCLUSÃO: O ângulo transepicondilar cirúrgico apresentou valores médios correspondentes aos da população caucasiana. Os instrumentais estão adequados, porém nenhum parâmetro anatômico se mostrou constante o suficiente para ser usado de forma isolada.

8.
Radiol. bras ; 48(5): 282-286, tab, graf
Artigo em Inglês | LILACS | ID: lil-764625

RESUMO

AbstractObjective:To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter.Materials and Methods:A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software.Results:The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from –2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from –2.09° to 12.2°.Conclusion:The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.


ResumoObjetivo:Definir o padrão de rotação do fêmur distal em população brasileira, correlacionar esse padrão com o sugerido pelos instrumentais de artroplastia e analisar a variabilidade de cada parâmetro anatômico.Materiais e Métodos:Foram avaliados 101 exames de ressonância magnética no período compreendido entre abril e junho de 2012. A coleta dos dados epidemiológicos foi feita pelo sistema informatizado da instituição de imagem, sendo 52 pacientes masculinos e 49 femininos. As mensurações foram feitas no plano axial, correlacionando e triangulando com os outros planos. Utilizamos como referência para as medidas angulares a linha condilar posterior. Na sequência, especificamos o eixo transepicondilar anatômico, cirúrgico e a linha troclear anteroposterior. As angulações entre a linha de referência e as linhas estudadas foram calculadas pelo software da instituição.Resultados:Foi encontrada uma média de 6,89° na aferição do eixo transepicondilar anatômico em relação à linha condilar posterior, variando de 0,25° a 12°. O eixo transepicondilar cirúrgico apresentou média de 2,89°, variando de –2,23° (rotação interna) a 7,86°. O eixo perpendicular à linha troclear anteroposterior apresentou média de 4,77°, variando de –2,09° a 12,2°.Conclusão:O ângulo transepicondilar cirúrgico apresentou valores médios correspondentes aos da população caucasiana. Os instrumentais estão adequados, porém nenhum parâmetro anatômico se mostrou constante o suficiente para ser usado de forma isolada.

9.
Rev. bras. ortop ; 50(4): 422-429, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-761119

RESUMO

Analisar e descrever, com o joelho em extensão, a distância da artéria poplítea em três áreas específicas da região proximal da tíbia, por meio de ressonância magnética. MÉTODOS: Foram analisadas as imagens de 100 joelhos de pacientes submetidos a exame por ressonância magnética. A localização da artéria poplítea foi medida em três áreas distintas da região proximal posterior da tíbia. A primeira medida foi feita no nível da articulação do joelho (platô tibial). A segunda, a 9 mm distal do platô tibial. A terceira, ao nível da tuberosidade anterior da tíbia (TAT). RESULTADOS: As distâncias entre a artéria poplítea e o platô tibial e a região da TAT foram significativamente maiores no sexo masculino do que no feminino. As distâncias entre a artéria poplítea e a região 9 mm distal do platô tibial e a TAT foram significativamente maiores na faixa acima de 36 anos do que na faixa ≤ 36 anos. CONCLUSÃO: O conhecimento da posição anatômica da artéria poplítea, demonstrada por estudos de RM, é de grande relevância no planejamento de procedimentos cirúrgicos que envolvam a articulação do joelho. Com isso, podem-se evitar lesões iatrogênicas devastadoras, principalmente em regiões proximais ao platô tibial e em pacientes jovens.


To analyze and describe the distance from the popliteal artery to three specific areas of the proximal region of the tibia, with the knee extended, by means of magnetic resonance. METHODS: Images of 100 knees of patients who underwent magnetic resonance examinations were analyzed. The location of the popliteal artery was measured in three different areas of the posterior proximal region of the tibia. The first measurement was made at the level of the knee joint (tibial plateau). The second was 9 mm distally to the tibial plateau. The third was at the level of the anterior tuberosity of the tibia (ATT). RESULTS: The distances between the popliteal artery and the tibial plateau and ATT region were significantly greater in males than in females. The distances between the popliteal artery and the regions 9 mm distally to the tibial plateau and the ATT were significantly greater in the age group over 36 years than in the group ≤36 years. CONCLUSION: Knowledge of the anatomical position of the popliteal artery, as demonstrated through magnetic resonance studies, is of great relevance in planning surgical procedures that involve the knee joint. In this manner, devastating iatrogenic injuries can be avoided, particularly in regions that are proximal to the tibial plateau and in young patients.


Assuntos
Humanos , Masculino , Feminino , Artéria Poplítea/anatomia & histologia , Joelho , Espectroscopia de Ressonância Magnética
10.
Rev. bras. ortop ; 48(3): 257-262, May/June/2013. tab
Artigo em Inglês | LILACS | ID: lil-680870

RESUMO

OBJECTIVE: to compare the laboratorial results of opening suction drainage 6 hours and 12 hours after total knee arthroplasty surgery. METHODS: prospective and randomized study in 88 patients undergoing with total knee arthroplasty in two groups: in one group the opening suction drainage was performed 6 hours (n = 45) after the surgery and in the other 12 hours (n = 43) after the surgery. RESULTS : the outcome was a significant fall in the three laboratorial variables (hemoglobin, red blood cells and hematocrit) between the pre and post-operative in the total sample and in the six and 12 hour opening suction drainage groups. In the group with opening suction drainage after 12 hours, the drainage volume was significantly lower than in the group with opening suction drainage after 6 hours (p = 0.0003). However, no significant difference was observed in the absolute delta of the laboratorial variables between the two groups. CONCLUSION: the opening suction drainage in six and 12 hours did not show significant difference from the laboratorial values although the volume of the blood drained was higher in the opening suction drainage in six hours. .


OBJETIVO: Comparar os resultados laboratoriais da abertura do dreno seis e 12 horas após a cirurgia de artroplastia total do joelho. MÉTODOS : Estudo prospectivo e randomizado em 88 pacientes tratados com artroplastia total do joelho com implante em dois grupos: um com abertura do dreno seis horas (n = 45) após a cirurgia e outro, 12 horas (n = 43) após a cirurgia. RESULTADOS : Existe uma queda significativa nas três variáveis laboratoriais (hemoglobina, hemácias e hematócrito) entre o pré e o pósoperatório na amostra total e nos grupos de tempo de abertura do dreno às seis e 12 horas. O grupo com tempo de abertura após 12 horas apresentou volume do dreno significativamente menor do que o grupo com tempo de abertura após 6 horas (p = 0,0003). Contudo, não foi verificada diferença significativa no delta absoluto das variáveis laboratoriais entre os dois grupos. CONCLUSÃO : A abertura do dreno em seis e 12 horas não demonstrou diferença significativa dos valores laboratoriais. Porém, o volume de sangue drenado foi maior com abertura do dreno após seis horas. .


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Canal de Drenagem do Solo , Próteses e Implantes
11.
Rev Bras Ortop ; 48(3): 257-262, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-31214542

RESUMO

OBJECTIVE: to compare the laboratorial results of opening suction drainage 6 hours and 12 hours after total knee arthroplasty surgery. METHODS: prospective and randomized study in 88 patients undergoing with total knee arthroplasty in two groups: in one group the opening suction drainage was performed 6 hours (n = 45) after the surgery and in the other 12 hours (n = 43) after the surgery. RESULTS: the outcome was a significant fall in the three laboratorial variables (hemoglobin, red blood cells and hematocrit) between the pre and post-operative in the total sample and in the six and 12 hour opening suction drainage groups. In the group with opening suction drainage after 12 hours, the drainage volume was significantly lower than in the group with opening suction drainage after 6 hours (p = 0.0003). However, no significant difference was observed in the absolute delta of the laboratorial variables between the two groups. CONCLUASION: the opening suction drainage in six and 12 hours did not show significant difference from the laboratorial values although the volume of the blood drained was higher in the opening suction drainage in six hours.

12.
Acta ortop. bras ; 13(5): 253-254, 2005. ilus
Artigo em Português | LILACS | ID: lil-420417

RESUMO

Os autores descrevem um caso raro de fratura de patela num paciente de 11 anos de idade onde o diagnóstico inicial não foi realizado. O diagnóstico "sleeve fracture" ou fratura por desluvamento foi revisado quanto a diversos aspectos como o diagnóstico clínico, o auxílio por meio de imagem e o tratamento mais adequado. Concluíram que, embora rara, a fratura deve ser lembrada e que o tratamento mais adequado é o cirúrgico.


Assuntos
Humanos , Masculino , Criança , Patela/cirurgia , Patela/lesões , Patela , Ossos da Extremidade Inferior , Patela/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...